Alarm Input Interface Module with PSU for IPTV
Item Number: 2320005103
Alarm interface module with PSU for IPTV
- 35mm DIN rail or direct surface mount
- 10/100 RJ45 Ethernet port
- Six (6) Dry contact inputs for connecting Alarm contacts, e.g.:
- General alarm
- Abandon
- Manual
- Fire Crew
- Fire ALL
- Other alarm
- When input contact is closed, every alarm input sends different UDP command to network server
- For example: "ALARM 1 ON", "ALARM 1 OFF", etc.
- Commands can be sent every 2ms (to have enough time for network to react)
- Customizable UDP commands up to 38 Characters, e.g. command could be "/ par1 / par2 - ALARM01 STATUS ACTIVE"
- Commands can be sent constantly during closed contact to have fail-safe function
- Priorities between alarms (1st General, 2nd Abandon, etc.)
- Web interface with all information
- Unit IP address, subnet mask, default gateway, Local (UDP) port
- Remote IP address, Remote (UDP) port
- On/Off commands for each alarm
- Fully web customizable
- Change unit IP address
- Change unit subnet mask
- Change default gateway
- Change unit local (receiving) port
- Set remote IP address
- Set remote (destination) port
- Customize each alarm command (every alarm ON and OFF commands)