GENERAL
Dimension (HxWxD) (mm) (H) 265 x (W) 190 x (D) 110 mm
Housing Aluminium Die-casting, Finishing: Black painted
Connectors IN: 5/8”-24 NEF F-Female to 3/8”-32 UNEF F-Female Adaptor
OUT: F-Female Connector (4 pcs)
Weight 3.5Kg
ELECTRICAL SPECIFICATION
RF Amplification Push-Pull Hybrid Module
Operation Gain IN-OUT w/ RA 100 KHz . 16.5 dB min.
Operation Gain IN-OUT 5 MHz 22.0 dB min.
Operation Gain IN-OUT 27 MHz 27.0 dB min.
Operation Gain IN-OUT 47~862 MHz 36.0 dB min. w
Operation Gain IN-OUT 47~862 MHz 42.0 dB min. w
200 ~ 890 16.0 dB*
Antenna 40 ~ 830 11. dB*
Noice Figure 7.5 dB max.
Flatness of Frequency Response +/- 2 dB max.
Max. Output Level, 2 signals 105 dBuV, 3rd order IMD
Variation of Gain with Temperature 0.02 dB/C max.
Manual Attenuation FM 40 ~ 110 MHz 0 ~ 20 dB
Manual Attenuation FM 170 ~ 890 MHz 0 ~ 20 dB
Current Consumption 150 mA +/- 10%
*) At 40 MHz -1.5 dB/oct.
GENERAL SPECIFICATIONS
Amplifier Current 200 mA max.
Ripple 2mV RMS Max.
AC Cord Schuko type § 4.8 mm 2 Round pin + Ground port, 1.5 m cord
Operating Temperature -40 to +60°C
EMC & SAFETY
EMC EN50083-2, EN61000-3-2/3-3
Safety EN60945, EN60065, EN60728
Dieletric Strength Test** 1 mA max.
Protective Earth Connection*** 1 V AC max.
**) Test by Voltage Meter applied between the protective earth contact of the mains plug and all accessible conductive parts.
***)Test by Hi-Pot tester.