Skip to main content

SPA-400D-V2 110VAC

Item Number: 2340130022

PA Main Unit,19" Rack 110 VAC

  • Input & priorities for 3 microphone panels
  • Input from CIS 3130 Talk Back system for PA control
  • Output to CIS Talk Back system
  • Input from entertainment system
  • PABX Input with zone presets
  • 6 zones, 400W Class-D 100V signal output
  • Input for 2 alarm panels
  • 2x Fire alarm input, all call and zone selection (fire crew)
  • Alarm mute during PA message
Marine 40x40 ico Onboard communication

The SPA-400D-V2 110VAC is part of the SPA-V2 series Public Address and General Alarm system that combines quality and value.  The SPA-V2 is an improved second generation version of the system that has been installed in thousands of marine vessels around the world. SPA-400D-V2 110VAC is the latest in the family that comes with our EA1400 Class-D amplifier.

The basic functionality module can support a single, non-redundant system and is delivered as a 19" rack that contains the main board, plus minimum one amplifier and optional functions.

Optional functions are:

  • Microphone and alarm panels
  • Dual system, with redundancy
  • Additional amplifiers
  • Alarm generators
  • PABX Interface
  • Redundant power supply
  • Digital message recorder
  • Chime generator
  • Entertainment
  • Output for voice data recording

On delivery, the rack is equipped and internally wired according to customer specifications. The system is tested and approved according to EN60945.

General
Rack size (WxHxD) 525 x 584 x 525 (19” 12HU)
Material Black painted steel
Mounting Floor
Voltage input Mains 110 VAC & 110 VAC emergency supply
Connections Plugable terminals for max. 2.5mm2 cable
Cable requirements Signal cable 0.75mm2 twisted outer screen
Amplifier 1x EA-1400, details on separate datasheet
Output 100V - 400W (400W music @ 55 °C continuously, 400W alarm @ 55 °C 30 min.)
Operating temperaure -15 to +55°C
Relative humidity <95%
Safety EN 60065
Tested according EN 60945
Optional rack sizes 19” 12,16, 20 and 24HU
EN60956 environmental category Protected
Compass safe distance 3.45 m
General

SPA-120-V2

SPA-120-V2

PA Main Unit,19” Rack Inclusive 120W Amplifier

Date Name Category Size Document
23.06.2023 MD-SDoC-2340130005-IHM-8003-41808-115341 Declaration 72.19 KB Login to download
22.09.2022 SPA-V2 DNV-GL Type Approval TAA00001D2-revision4. Certificate 556.78 KB Download
27.01.2022 A100K10370 SPA-V2 Configuration & Installation Manual Manual 4.06 MB Download
24.08.2020 A100K11939 EA1400/EA1600 Installation & User Manual Manual 1.43 MB Download
7.04.2020 Declaration of Conformity SPA-V2 Declaration 72.73 KB Download