Skip to main content
SPA PAGA 19 Inch Rack - Frontview
SPA PAGA 19 Inch Rack - Sideview
SPA PAGA 19 Inch Rack - Backside

SPA-D-V2-REDUNDANT

Item Number: 2340130007

PA/GA Class-D REDUNDANT Main Unit,19" RACK

  • Input priorities for 3 microphone panels
  • Input from CIS 3130 Talk Back system for PA control
  • Output  to CIS Talk Back system
  • Input from entertainment system
  • PABX Input with zone presets
  • 6 zones 100 V signal output
  • Input for 2 alarm panels
  • 2x Fire alarm input, all call and zone selection (fire crew)
  • Alarm mute during PA message
  • Powered by 230VAC with automatic switchover to 230VAC. *
Marine 40x40 ico Onboard communication

The SPA-D-V2-REDUNDANT is part of the SPA-V2 series public address and general alarm system combines quality and value. The SPA-V2 is an improved second generation system which in first generation version has been installed in thousands of ships around the world. The SPA-D-V2 REDUNDANT will be available together with 2x400 class D Amplifiers from the Vingtor Stentofon range of amplifiers. 

The EA1400 amplifier is cost efficient analog class D amplifier built for use in demanding environments such as marine and offshore. The amplifier is self monitoring  including basic monitoring of the speaker lines. The audio output channels can be monitored for line faults such as shorts circuits and ground faults.

SPA-D-V2-REDUNDANT

is a single 12HU cabinet with full A-B redundancy PAGA system.

INCLUDES:

  • 2x SPA-TERMINALBOARD-V2
  • 2x SPA-EE3-V2 ALARM GENERATOR
  • 2x SPA-AL-REL-V2
  • 2x AC/DC PSU
  • 2x WIRING PREPARED FOR EA  AMPLIFIERS

 

NOTE: Dual access panels must be used for connection and correct redundancy functionality.

NOTE: Add 2x EA1400  amplifier to SPA-D-V2-REDUNDANT. For more than 2 amplifiers; add 2x SPA-MUL-V2 and SPA-EXP (Rack expansion).

 

 

 

General
Rack size (WxHxD) 525 x 600 x 525 mm (19” 12HU)
Material Black painted steel
Mounting Floor
Voltage input Mains 230 VAC / 230 VAC
Connections Plugable terminals for max. 2.5mm2 cable
Cable requirements Signal cable 0.75mm2 twisted outer screen
Amplifier None. Prepared for 2x EA amplifier up to 600W
Output N/A
Operating temperaure -20 - +55°C
Relative humidity <95%
Safety EN 60065
Tested according EN 60945
EN60945 environmental category Protected
Compass safe distance 3.45 m
General

Date Name Category Size Document
8.11.2024 CCS TA Certificate - SPA-V2 - 2029.08.26 - BG24PTA00002_06 Certificate 315.72 KB Login to download
31.10.2024 ABS TA certificate -SPA-V2 2028.09.28.pdf Certificate 109.59 KB Login to download
11.09.2023 SPA-V2 - CRS (Croation Registry of Shipping) - QFO-PTO Certificate 629.8 KB Download
23.06.2023 MD-SDoC-2340130007-IHM-8003-41808-149106 Declaration 72.16 KB Login to download
22.09.2022 SPA-V2 DNV-GL Type Approval TAA00001D2-revision4. Certificate 556.78 KB Download